All basic unit chassis shall be fabricated of heavy gauge galvanized steel panels insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform to UL 181 for...
All unit chassis shall be fabricated of heavy gauge galvanized steel panels able to meet 1,500 hour salt spray test per ASTM B-117. All exterior panels shall be insulated with 1/2″ thick, 1.5 pound per cubic foot, dual density fiberglass insulation rated...
All unit chassis shall be fabricated of heavy gauge galvanized steel panels able to meet 1,500 hour salt spray test per ASTM B-117. All exterior panels shall be insulated with 1/2″ thick, 1.5 pound per cubic foot, dual density fiberglass insulation rated...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel panels. All exterior panels shall be insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel panels. All exterior panels shall be insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel panels. All exterior panels shall be insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel panels. All exterior panels shall be insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel panels. All exterior panels shall be insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel panels. All exterior panels shall be insulated with 1/2″ thick, 3.35 pound per cubic foot, dual density fiberglass insulation rated for a maximum air velocity of 3600 f.p.m. Insulation shall conform...
All unit chassis shall be fabricated of heavy gauge cold-rolled steel cabinet painted in epoxy powder coated soft white paint. All exterior panels shall be insulated with 1/2″ thick, 1.5 pound per cubic foot, dual density fiberglass insulation rated for a maximum...